How an air to air heat pump is fitted
A single wall unit is usually fitted in a day: one hole of about 65 mm through the wall for the pipes, the drain and the cable, the outdoor unit on brackets or feet, a dedicated electrical circuit, then a vacuum and pressure test and a run in heating and cooling. A multi split or a ceiling unit can take 2 days.
The visit, the fitting day step by step, the mess, and what you should be handed at the end.
Free and no obligation. Your request goes to one installer in your county, not a list.
- Usually a dayone wall unit
- Up to 2 daysa multi split or ceiling unit
- 65 mmone hole through the wall
- F-gascertified, for the refrigerant

The visit before the fitting
The installer looks at the room and works out the unit size, finds the spot for the outdoor unit, follows the route the pipes will take and opens the fuse board to see whether there is room for a new circuit. That visit is what turns a range into a written price.
The day, step by step
- Mark the positions. The indoor unit, the outdoor unit and the route between them, agreed with you.
- Fix the indoor unit's plate to the wall, level, with room for the air.
- Drill one hole of about 65 mm through the wall, angled down to the outside for the drain.
- Put up the outdoor unit on brackets with anti-vibration mounts, or on feet.
- Run the pipes, drain and cable through the hole and in trunking to the outdoor unit.
- Wire the unit on its own circuit from the fuse board.
- Vacuum and pressure test the copper pipes, then let the refrigerant into them. This is the F-gas certified part of the job.
- Run it in heating and cooling, set it up on the controller or the app, and show you how it works.
Price your system
Three taps and the price shows as you go. Your name and number come last, and only if you want an installer to price it.
An open-plan room or extension, one indoor unit, heating still to confirm: €2,500 to €4,000.
How the price is worked out
The figure is what Irish installers charge for the whole job, supplied and fitted: the indoor and outdoor units, the pipes between them, the electrical connection and the fitting. One room uses the single-room range, or the large-room range for an open-plan room or an extension. Two rooms, and three to five rooms, are multi split ranges. Ducted systems and rooms still to count read priced on a visit. What heats the home now changes the grant line, never the price. Sellers differ on VAT, so ask whether it is in the figure. Use it to plan with. It isn't a quote: an installer prices yours after seeing the rooms and the walls.
Dust, trunking and making good
Drilling one hole makes some dust, and a careful installer covers the floor and furniture under it. Plain white trunking is standard outside and where pipes show inside. Painted trunking, pipes hidden in the wall and plastering round the hole are extras, so ask what the price includes.
What you should have at the end
- The system run in both heating and cooling in front of you.
- The controller or app set up, and the timer explained.
- The maker's data sheet and the manual.
- The guarantee in writing, with any service it needs.
- The F-gas certificate details of the technician and the company.
Other systems and spaces
Single room systemsOne indoor unit and one outdoor unit. €1,850 to €3,500 fitted, more for a big open-plan room.
Multi split systemsOne outdoor unit and two to five rooms. Two rooms cost €4,000 to €6,500 fitted.
ApartmentsWhat the planning exemption leaves out, and who to ask before anything goes on the wall.
Extensions and open-plan roomsBig rooms with a lot of glass. €2,500 to €4,000 for one large room, fitted.
Attic roomsRooms under the roof that are cold in January and hot in July.
Garden roomsAn office or studio out the back, heated and cooled without pipes from the house.Questions before you buy
How long does it take to fit an air to air heat pump?
Usually a day for one wall unit. A multi split or a ceiling unit can take 2 days.
How big a hole goes through the wall?
One hole of about 65 mm for the pipes, the drain and the cable.
Does it need its own electrical circuit?
Yes. A unit runs on its own circuit from the fuse board.
Who can connect the refrigerant pipes?
The technician who connects, fills or opens the refrigerant circuit needs an F-gas personnel certificate, and the company needs a company F-gas certificate. Doing the work without one is an offence. Ask for both before the job is booked.
Is it messy?
Some dust from one hole. Ask the installer to cover the floor, and check whether making good is in the price.