Heating and summer cooling with one heat pump
An air to air heat pump moves heat rather than making it. In winter it takes heat from the outside air and puts it into the room; in summer it runs in reverse and takes heat out of the room. On SEAI's figures it gives 2.5 to 4.2 units of heat over a season for each unit of electricity.
How the same unit heats in winter and cools in summer, why it drips and what it does not do.
Free and no obligation. Your request goes to one installer in your county, not a list.
- 2.5–4.2units of heat per unit of electricity
- Both waysheats in winter, cools in summer
- No hot waterit heats the air only
- 8.5–13.6 ca kWh of heat, on SEAI's figures

How it heats
A refrigerant runs in a closed loop between the two units. In the outdoor unit it is colder than the outside air, so it takes heat from that air even on a cold day. The compressor squeezes it, which makes it hotter, and in the indoor unit it gives that heat to the room while a fan blows the warm air out. Then it goes back outside for more.
Electricity runs the compressor and the fans. The heat itself comes from outside, which is why one unit of electricity brings in more than one unit of heat.
How it cools
In cooling mode the loop runs the other way. The indoor unit takes heat out of the room air and the outdoor unit throws it outside. As the air passes over the cold coil indoors it also drops its moisture, which is why a unit in cooling mode drips into its drain and why a room feels fresher than the temperature alone suggests.
Price your system
Three taps and the price shows as you go. Your name and number come last, and only if you want an installer to price it.
An open-plan room or extension, one indoor unit, heating still to confirm: €2,500 to €4,000.
How the price is worked out
The figure is what Irish installers charge for the whole job, supplied and fitted: the indoor and outdoor units, the pipes between them, the electrical connection and the fitting. One room uses the single-room range, or the large-room range for an open-plan room or an extension. Two rooms, and three to five rooms, are multi split ranges. Ducted systems and rooms still to count read priced on a visit. What heats the home now changes the grant line, never the price. Sellers differ on VAT, so ask whether it is in the figure. Use it to plan with. It isn't a quote: an installer prices yours after seeing the rooms and the walls.
Winter, frost and the drip outside
In cold, damp weather frost forms on the outdoor unit's coil. The unit melts it with a short defrost, and the water runs out of the bottom. That is normal, and it is why the installer leaves a drain or a gravel bed under a unit on the ground.
What it does not do
- Hot water. SEAI's technical standard says an air to air system gives space heating only. The water needs its own heater.
- Rooms with no unit. Each unit heats its own room and a little of the space beside it.
- A leaky house. It does its job where the heat stays in: insulation first.
The settings that matter
- Heat, cool or dry. Dry mode takes moisture out with less cooling.
- One steady temperature. It runs most efficiently holding a temperature, not chasing big jumps.
- The timer. Warm the room before you use it, cool it before bed.
- Doors closed. It heats and cools the room it is in, not the hall.
Other systems and spaces
Single room systemsOne indoor unit and one outdoor unit. €1,850 to €3,500 fitted, more for a big open-plan room.
Multi split systemsOne outdoor unit and two to five rooms. Two rooms cost €4,000 to €6,500 fitted.
ApartmentsWhat the planning exemption leaves out, and who to ask before anything goes on the wall.
Extensions and open-plan roomsBig rooms with a lot of glass. €2,500 to €4,000 for one large room, fitted.
Attic roomsRooms under the roof that are cold in January and hot in July.
Garden roomsAn office or studio out the back, heated and cooled without pipes from the house.Questions before you buy
Does an air to air heat pump cool as well as heat?
Yes. An air to air heat pump runs in reverse in summer and cools the room, which is why the same unit is sold as air conditioning. In winter it heats, and it is the heating that SEAI's grant is about.
How can it heat when it is cold outside?
The refrigerant in the outdoor unit is colder than the outside air, so it still takes heat from it. The compressor then raises that heat to room temperature.
Why does the outdoor unit drip in winter?
Frost forms on its coil in cold, damp weather, and the unit melts it with a short defrost.
Is an air conditioning heat pump the same thing?
Yes. A split air conditioner that heats is an air to air heat pump.
Does it heat water?
No. An air to air heat pump heats the air in the rooms and makes no hot water. The water stays with whatever heats it now, and if a boiler is being taken out, an immersion or a hot water heat pump takes it over.
How efficient is it?
SEAI puts the seasonal efficiency of an air to air system at 2.5 to 4.2: that many units of heat for each unit of electricity over a season.
Everything on this site
Systems and spaces
Costs, grant and rules

See the price before anyone rings
Pick the space, the number of rooms and what heats it now. When you want a firm price, it goes to a single installer in your county.